STR #911

Application:FLTK Library
Status:1 - Closed w/Resolution
Priority:2 - Low, e.g. a documentation error or undocumented side-effect
Scope:3 - Applies to all machines and operating systems
Subsystem:Core Library
Summary:Fl_Value_Sliders do not receive focus
Version:1.1-current
Created By:Portale
Assigned To:matt
Fix Version:1.1.7
Update Notification:

Receive EMails Don't Receive EMails

Trouble Report Files:

No files


Trouble Report Comments:


Name/Time/Date Text  
 
#1 Portale
09:23 Jun 12, 2005
Fl_Value_Sliders don't receive a focus when clicking on them or when even changing the value. They only receive it when changing the focus via the TAB key.

This is observable in the valuators, line_style, output and arc test apps.
 
 
#2 matt
01:31 Jul 16, 2005
Fixed in Subversion repository.  
     